Part Number: EH3-B100-F2 | Manufacturer: Siemens Energy And Automation Inc |
NSN: 5925-01-078-2374 | Item Name : Circuit Breaker |
CAGE Code: 66842 | FSC: 5925 Circuit Breakers |
Alternate P/N : EH3B100F2 |
Part number EH3-B100-F2, which is associated with national stock number 5925010782374, is now available in our stock. EH3-B100-F2, which is a Circuit Breaker is manufactured by Siemens Energy And Automation Inc. This part has an FSC code of 5925 Circuit Breakers.
For a quote on this part EH3-B100-F2, fill out the form provided below with as much detail as possible. The more information you provide, the better our quote will fulfill your specific needs. Once your request is submitted, we will get back to you with a quote in just 15 minutes.
PlaneParts360.com is owned and operated by ASAP Semiconductor, an AS9120B, ISO 9001:2015, and FAA AC 0056B certified company. We have huge stock of Siemens Energy And Automation Inc NSN parts. There are more than 10 million national stock numbers, and over 26 categories of distinct federal supply codes provided on our website. All the parts of national stock numbers 5925010782374 listed on our website are available at competitive prices. ASAP Semiconductor is known for providing outstanding quality control and fast shipping to our customers. This results in little to no downtime in the ordering process.
The national stock number, applied to part number EH3-B100-F2, is a label that informs consumers that the part is being used, stocked, and distributed within the federal supply system. National stock numbers can have multiple part numbers under it depending on whether it has multiple manufacturers for the same part. Do you have questions related to any of the parts listed on our website? If so, our experienced sales reps are here and eager to help you in any way they can. You can get in touch with our professionals on our toll-free number +1-714-705-4780 or email your (BOM) Bill of Materials to sales@planeparts360.com.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-078-2374 Item Description: Circuit Breaker | 5925 | 010782374 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | S | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Eh3-B100-F2 | 5 | 1 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 5.984 INCHES MINIMUM AND 6.016 INCHES MAXIMUM |
ADAT | BODY WIDTH | 4.484 INCHES MINIMUM AND 4.516 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 5.109 INCHES MINIMUM AND 5.141 INCHES MAXIMUM |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.484 INCHES MINIMUM AND 1.516 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 4.577 INCHES MINIMUM AND 4.609 INCHES MAXIMUM |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.484 INCHES MINIMUM AND 1.516 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJEC | BOSS HEIGHT | 0.202 INCHES MINIMUM AND 0.234 INCHES MAXIMUM |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 3.983 INCHES MINIMUM AND 4.015 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 3 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 100.0 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 15000.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 2 ALARM |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT EACH POLE |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS PROOF |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CRTK | SWITCH TERMINAL TYPE | WIRE LEAD |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
PMLC | PRECIOUS MATERIAL AND LOCATION | TERMINAL AND C0NTACT SURFACES SILVER |
PRMT | PRECIOUS MATERIAL | SILVER |
THSD | THREAD SERIES DESIGNATOR | UNC |
TTQY | TERMINAL TYPE AND QUANTITY | 6 QUICK DISCONNECT, FEMALE |
ZZZK | SPECIFICATION/STANDARD DATA | 01714-G376972-1 MANUFACTURERS SOURCE CONTROL |
If You Want to Stay Up to Date On Our Latest Promotions, You Can Sign Up for ASAP Semiconductor’S Email Campaign by Clicking Here.
Request for Quote